FIRE DOOR SAFETY

Why use us? We have Approved Inspector status

 

We have a wealth of knowledge and understanding of fire risk assessments and fire doors. We take a very sensible approach to nominal, notional and upgraded fire doors which will satisfy your local inspecting fire officer and meet the requirements of the Regulatory Reform Fire Safety Order 2005.

We also provide a very cost-effective solution with easy-to-understand results. No fuss just straight forward advice in layman’s terms

 

 

Nominal Fire Doors

 

A nominal fire door is a timber-based door providing a fire door resistance performance for a specified period of time. However, they are not the same as certified fire doors which have undergone fire door resistance performance tests to give an indication of fire performance and determine their fire door rating. The performance of the door is simply relied upon by the fire door inspector’s opinion/experience.

 

Notional Fire Doors

 

A notional fire door is a fire door that satisfied the standards applicable to fire door resistance at the time of construction. These types of doors are therefore not the most up-to-date with the latest codes, regulations and tests, and may not have been fitted with intumescent strips and smoke seals, and may not even be constructed correctly.

 

Upgraded Fire Doors

 

An upgraded fire door is a notional fire door that has been updated with additional fittings such as intumescent strips, smoke seals, hinges, self-closing device and sometimes even a protected letter box, if required.

However, you cannot simply add these additions to any door and call it an upgraded fire door. The overall condition and core construction of the door itself affects the fire resistance, so it needs to match a certified fire door to provide any satisfactory performance. If you added these extras to a lightweight door with thin panels, you would not be making a fire door.

 

 

Why do your fire doors need to be inspected?

 

Under the Regulatory Reform Fire Safety Order 2005 building managers (responsible persons) have a legal duty to ensure all fire protection assets within their buildings are fit for purpose and correctly maintained.

 

Fire doors are subject to day-to-day wear and tear, even a small amount of damage can reduce the efficacy of a fire door by as much as 50% of its intended fire rating. Regular fire door inspections are an essential part of building maintenance.

 

A thorough fire door inspection should be carried out by a suitably competent person and include a full check of all aspects of the door checked back to its intended installation.

 

Properly functioning fire doors save lives!

 

 

1. Fire door schedule (This is where we assess all doors within a building to determine which doors need to be maintained as fire doors/final exit doors and those that don’t).

A review into the types of doors that should be installed and what ratings they are required to have needs to be carried out before any inspections take place. This information (usually found on site plans and fire strategy documentation) is used as a baseline.

 

 

The fire door inspection below will then cross-reference the actual findings of the doors against the schedule.

 

 

2. Inspection ( this is were each fire door/final exit door is assessed against a comprehensive check list)

An inspection of each fire door will check all aspects of the door’s features and hardware, ensure the door/s meet the building’s fire strategy and inspect for wear and tear that may reduce the fire door’s efficiency if the worst happens.

 

 

All aspects of the inspection should be recorded and evidenced to protect the responsible person in case of a fire.

 

 

3. Maintenance ( once the doors have been inspected by us we provide information for you to pass on to your contractor to carry out any remedial works or in some cases the replacement of doors.

Regular repairs should be carried out to industry guidelines (ideally to a 3rd party certificated standard such as BM Trada Qmark) ensuring that any repairs carried out are compliant and reinstating the fire door’s resistance.

 

 

Ongoing fire door inspections should be scheduled at suitable intervals to pick up damage before it becomes a major issue, as a guideline 6 monthly for standard usage is a good baseline.

 

 

 

Typical Costs

 

 

£8.00 per door – Building with over 60 doors.

£10.00 per door – Buildings with 25 – 59 doors

£12.00 per door – Buildings with 10 -24 doors

£95.00 in total for buildings with less that 10 doors